 |
|
Double Stage Pressure Regulator |
Diffusion Resistant Gas Pressure
Regulators:
CSL offers a wide comprehensive range of gas control equipment including
gas regulators, gas analyzers, cylinders, line regulators, gas supply panels, laboratory outlet
points, valves, tube fittings, high pressure gas sampling bottles
CSL regulators have been designed to meet the demand of high purity
corrosion resistance product.
Pressure Gauges:
CSL provide dial type/digital pressure gauges in various sizes and ranges
(0-300 Bar) which are calibrated with master gauges Traceable NPL
Accessories:
Fine control needle valves, S.S. 316 gas sampling valves, flowmeters,
tubings, ampules breakers, fittings, couplings, etc.
Gas Sampling Bottle:
 |
|
Gas Sampling Bottle |
We offer gas sampling bottles that are specially designed to
collect and store high pressure gas samples from the field & transport
the same to laboratories. Superior in quality, these bottles pass through
rigorous quality control tests and inspections to ensure maximum integrity
and cleaning process for effective corrosion resistance.
Designed as per exact industry standards and guidelines, the gas sampling
bottles are available in different sizes and specifications and are
available at most competitive prices.
Gas Manifold:
Our Gas Manifold provides effective solutions for problems such as
contamination and lack of control of feed stock gases. These gas manifold
pass through rigorous quality control tests to ensure zero-defects and high
performance. Some of the salient features of our manifolds are:
- Short gas paths to improve control
- Compact design, which enables integration into confined spaces
- Smooth internal surfaces and low mixing volume
(Model No. - DGA 7045)
CSL offers a simple inexpensive unit Model CSL:DGA-7045 for transformer oil
dissolved gas analysis. The system consists of gas extraction unit. to

extract
the gases from the transformer oil. The oil is stirred during extraction
under vacuum at a temperature of 80 to 90 Deg C by employing a magnetic
stirrer. The volume of gas is measured. The Model CSL:DGA-7045 is specially
tailored for this analysis. It consists of FID and TCD detectors with
suitable columns such that Methane, Ethane, Ethylene, etc are separated out
and detected by FID, CO and CO2 is converted in to methane by methanator
unit and detected by FID. Hydrogen is detected through TCD using argon as
carrier gas. With unique system design and integration software the whole
operation and complete analysis is completed in 15 minutes. Calibration gas
standards required for the unit comes in two mixtures one having
hydrocarbons and the other having hydrogen CO and CO2. CSL offers complete
system with calibration gases, carrier gas along with gas extraction unit
and chromatographic unit. We also under take the analysis of DGA in our lab.
We ,
M/s CSL is working as authorized dealer of M/s ECOM for
marketing, installation, commissioning and after sales service for their
world-class HPLC products for India region.
M/s ECOM
M/s ECOM is a renowned supplier of complete HPLC systems and
associated equipment for liquid chromatography for flash, preparative and
analytical purposes. Their products in brief are summarized below. For
detail you may visit their web site
www.chromatography-hplc.com or
contact us.
HPLC System :
| Isocratic
analytical system |
For
routine analysis at one wavelength with high sensitivity |
| Izocratic
preparative system |
For
preparative applications at two wavelength |
| Gradient
analytical system |
For
complicated analysis at different wavelengths in |
| Isocratic
analytical system with detector Sapphire 600 |
For
routine analysis at variable wavelength with high sensitivity |
Pumps :
Analytical, preparative, gradient and membrane pump for use in HPLC.
| ALPHA
10 Isocratic Pump |
(0.01 - 10
mL/min, 40 MPa) |
| ALPHA
50 Isocratic Pump |
(0.05 - 50
mL/min, 30 MPa) |
| ALPHA
100 Isocratic Pump |
(0.1 - 100
mL/min, 15 MPa) |
| BETA
10 Gradient Pump |
(0.01 - 10
mL/min, 40 MPa) |
| BETA
50 Gradient Pump |
(0.1 - 50
mL/min, 28 MPa) |
| KAPPA
10 One Piston Pump |
(0.1 - 10
mL/min, 40 MPa) |
UV-VIS Detector :
Detectors for analytical, preparative and flash HPLC applications.
UV-VIS Detectors with high flow cell :
ECOM produce three type of detectors for external cell connecting. The cell
is connected using fiber optic cable with SMA connectors.This solution is
used if is the cell located at tested unit (for example by ITP) or if is the
cell located in explosive or contaminated area.
CE for capillary electrophoresis :
- Detectors for capillary electrophoresis
- ECOM designed SAPPHIRE UV-VIS Variable Wavelength Detector version,
suited for CE (Capillary electrophoresis).
- Cell for quartz capillaries implementation is located at detector
front panel.
Auto samplers :
Autosamplers for automatic samples injection to systems of HPLC,
analytical, preparative and flash chromatography.
Inject valves :
Analytical and preparative injectors for use in systems of HPLC,
analytical, preparative and flash chromatography
Switch valves :
Switch valves for column switching. Change flow path. Used in systems of
HPLC,analytical, preparative and flash chromatography.
Holders for injectors :
Holders of valves or columns for assembly on pumps, column ovens or on
table
External loops :
External sample loops for injectors.
Hamilton syringes :
Holders of valves or columns for assembly on pumps, column ovens or on
table
Holders for injectors :
Hamilton syringes with cemented or removable needle and LUER
needle. For injections in HPLC, analytical chromatography.
- Cemented needle
- Removable needle
NOTE: In addition to above we are in position to give complete
solution for HPLC system and related accessories.
M/S E INSTRUMENT - Greenline Series
Combustion and Environmental Monitoring Flue Gas Analyzers :
Green Line 2000 :
The Complete Portable Tool for the Tuning & Maintenance of Boilers,
Burners, Engines & Furnaces
- Measures up to 2 gases: O2, CO
- Built-in Impact Printer (NonThermal)
- Stores up to 250 Samples
- Low NOx Capabilities NO/NOx & SO2 Emission Analyzer
- CxHy UnCombusted HydroCarbons
- Draft & Differential Pressure Sensors
- External Water Trap for Condensate Removal
- Gas and Air Temperature Measurement
- Ionization Flame Tester
- Ambient CO Monitor (w/ Internal or External Sensor)
- Automatic Over Range Protection for CO Sensor
- Temperature & Humidity Meter
- Windows Software
Green Line 4000 :
The Complete Portable Tool for Tuning & Maintenance of Boilers,
Heaters, Dryers, Kilns, Furnaces, Stationary Internal Combustion Engines,
Turbines, & Chemical Laboratories.Water, Air, and Surface Temperature
Measurements
- Measures up to 4 Gases of your choice: O2, CO, NO, NO2, SO2, CxHy
- Built-in Impact Printer (non-thermal)
- Stores up to 250 Samples
- Low NOx Capabilities NO/NOx & SO2 Emission Analyzer
- CxHy UnCombusted HydroCarbons
- Draft & Differential Pressure Sensors
- External Water Trap for Condensate Removal
- Gas and Air Temperature Measurement
- Ionization Flame Tester
- Ambient CO Monitor (w/ Internal or External Sensor)
- Automatic Over Range Protection for CO Sensor
- Temperature & Humidity Meter
- Windows Software
Green Line 6000 :
The Complete Portable Tool for Tuning & Maintenance of Boilers,
Heaters, Dryers, Kilns, Furnaces, Stationary Internal Combustion Engines,
Turbines, & Chemical Laboratories.
The Essential Tool for any Plant Engineer
- Measures up to 6 Gases of your choice: O2, CO, NO, NO2, SO2, CxHy,
H2S
- Low NOx Capabilities
- Main Control Unit & Remote Control Unit w/ Built-in Printer
- Draft & Differential Pressure Sensors
- 1000 Full Analysis Memory
- Windows Software for Real-time Data Logging, Graphing, and Reporting
- Built-in Cooler with Automatic Condensate Removal
- Automatic Protection for CO Sensor w/ Purge Pump
- Long-Term Monitoring and Data Logging
- Electronic Flow-Meter
- Aux 4-20mA Inputs
- Graphic Display w/ Menu
- Gas Sniffer Probe
- Ambient CO Monitoring Probe (Visible & Audible Alarm)
- Automatic Over Range Protection for CO Sensor
Green Line 8000 :
The GreenLine 8000 is the Most Powerful & Advanced Portable Gas
Analyzer on the Market, and is a Complete, Portable Tool for EPA Compliance
Level Emissions Monitoring.
- Measures up to 9 Gases of your choice: O2, CO, NO, NO2, SO2, CxHy,
H2S w/ Temperature Compensated EC Cells and NDIR Bench for CO2, CO, CxHy
Measurement
- Monitor True Low NOx (NO+NO2) for ranges of Min: (0-25 ppm), Max:
(0-500 ppm) with 0.1ppm Resolution
- Main Control Unit & Remote Control Unit w/ Built-in Printer
- Draft & Differential Pressure Sensors
- Full Compliance to EPA Protocol (CTM-030, CTM-034)
- Built-in Peltier Chiller with Automatic Condensate Removal
- Heated Hose and Heated Probe Head
- 9000 Full Analysis Memory
- Windows Software for Real-Time Data Logging, Graphing, and Reporting
- Automatic Protection for CO Sensor w/ Purge Pump
- Long-Term Monitoring w/ Automatic Water Condensate Drain
- Electronic Flow-Meter
- Aux 4-20mA Inputs
- Gas Sniffer Probe